Water Mist Cannon Turbine

Description

  • A Water Mist Jet Turbine shall be installed on top of the fire tender at a suitable location. The fire fighting turbine shall be hydraulically driven.
  • It should atomize up to 3500 l/min of water into fine droplets and throw them over high distance.
  • High tech fan for max efficiency
  • Nozzle configuration for fine water mist
Technical Details
Flow700 LPM Ring Sprayer (360 nozzles)
6000 LPM Center Monitor (min. 5 inch water ways)
Inlet Connections3 or 4 x 63 mm (Instantaneous) or Header Manifold
Working Pressure5 to 16 Bars
Air Flow70.000 m³/h (Primary)
140.000 m³/h (Secondary)
Turbine Rotation+50° to -20° Vertically
360° horizontally
Power Consumed40 – 55 HP
DimensionsApprox. 1800 mm x 1420 mm x 1870 mm
Weight800-1000 Kgs
DriveThe turbine shall be driven hydraulically. Gearbox PTO of fire tender shall provide Power for Hydraulic Pump which will pump high pressure Hydraulic Oil into circuit.
MountingThe entire Mist Unit shall be mounted securely on a platform which can carry mist unit completely above chassis level for an unrestricted movement of unit in full rotation. The platform shall be hydraulically driven deriving its power from Gearbox PTO operated Hydraulic Pump.
ControlThe unit shall be equipped with wireless radio controls for all operations with range of 100 meters & shall also have a manual back up controls in the vehicle.
Foam UsageSuitable for all kind of foam and mixing rate.
Additional Attachment Systems1. Monitor Nozzle – 6000 LPM Flow Operated by Remote Control
2. Medium Expansion Foam Tube – Throw 35 meters – 800 LPM
3. Heavy Duty Foam Tube – Throw 60 meters – 3000 LPM
4. 3 x 33 meter Ventilation Duct + Alum. Carriage Boxes

You may also like…